medical equipment

01 Typical Requirements for Magnetic Devices in Medical Equipment
Medical electronic systems typically have the following characteristics:
Extremely high requirements for electrical safety and isolation
Need stable power supply with low noise and low ripple
Long term continuous operation, emphasizing reliability
Must meet strict medical safety and EMC standards
Therefore, the quality and consistency of magnetic devices are particularly crucial.
Application of Transformer 02 in Medical Equipment
Main application scenarios
Medical equipment AC/DC, DC/DC power supply
Safe isolation power supply for patient contact devices
Auxiliary control and signal isolation module
core function
Electrical isolation: prevent leakage risk and ensure patient safety
Voltage conversion: providing appropriate voltage for different functional modules
Improve system reliability: adapt to long-term stable operation requirements
Isolation transformer is a critical safety component in the power supply system of medical equipment.


03 Application of Inductors in Medical Equipment
Main application scenarios
DC/DC power storage and filtering
Smooth output current and ripple suppression
EMI common mode/differential mode filtering
Signal power supply noise control
core function
Energy storage and current smoothing
Reduce noise and improve power supply stability
Suppress electromagnetic interference and ensure signal quality
Inductance in medical equipment helps to achieve a quiet and stable power environment.
04 Collaborative Application Relationships in the Medical System
In practical applications, transformers and inductors usually work together:
Transformers are responsible for isolation and voltage conversion
Inductors are responsible for energy storage, filtering, and current stability
Both jointly ensure the safety, stability, and low noise performance of the power supply
This collaborative structure is widely used in medical power modules and control systems.


05 Relationship between Transformer and Inductance
Project Transformer Inductor
Main functions include voltage conversion, safety isolation, energy storage, filtering, and stable current
Is isolation necessary? Usually not necessary
Typical locations include medical power supply, isolation module DC/DC, filtering EMI
System value: Patient safety, reliability, low noise, stability
Summary:
Transformers are responsible for "safety isolation and energy conversion",
Inductors are responsible for "current stability and noise control".
The two together form the magnetic foundation for the reliable and safe operation of medical equipment.
06 Development Trends of Magnetic Devices in Medical Equipment
With the development of medical equipment towards high precision, miniaturization, and intelligence, higher requirements have been put forward for magnetic devices:
Higher reliability and consistency
Lower noise and loss
Stricter safety isolation design
High quality transformers and inductors are important foundations for the safe and stable operation of medical equipment.